• 400kVA Cummins Silent Diesel Generator for Sale (NTAA85-G7A) (GDC400*S)
  • 400kVA Cummins Silent Diesel Generator for Sale (NTAA85-G7A) (GDC400*S)
  • 400kVA Cummins Silent Diesel Generator for Sale (NTAA85-G7A) (GDC400*S)
  • 400kVA Cummins Silent Diesel Generator for Sale (NTAA85-G7A) (GDC400*S)
  • 400kVA Cummins Silent Diesel Generator for Sale (NTAA85-G7A) (GDC400*S)
  • 400kVA Cummins Silent Diesel Generator for Sale (NTAA85-G7A) (GDC400*S)

400kVA Cummins Silent Diesel Generator for Sale (NTAA85-G7A) (GDC400*S)

Type: Basic Diesel Generator
Installation Method: Fixed
Stroke: Four Stroke
Cooling Method: Water Cooling
Output Type: AC Three Phase
Speed: Speed
Customization:
Diamond Member Since 2011

Suppliers with verified business licenses

Rating: 4.0/5
Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
GDC400*S
Conditions of Use
Land Use
Usage
Common Units
Landuse Type of Unit
Ordinary
Excitation Mode
AC Rotating Exciter
Engine
Cummins Brand, Mtu, Deutz Is Optional
Alternator
Stamford, Marathon, Engga
Controller
Dse, Smartgen Is Optional
Material
100% Famous Material
Test Load
25%, 50%, 75%, 100%, 110%
Voltage Range
110V-690V
Transport Package
in Strong Plywood
Specification
IECBS 5000, IEC 34, CCC, CE, ISO9001, SGS
Trademark
GOLDLINK (OEM supported)
Origin
China
HS Code
8502131000
Production Capacity
8000sets Per Year

Product Description

400kVA Cummins Silent Diesel Generator for Sale (NTAA85-G7A) (GDC400*S)

Performance Feature
Engine and alternator shall be mounted on a same frame steel skid.
Built-in damper for anti-vibration.
Small size, low weight, easy for operation, installation and maintenance.
World most famous brand diesel engine.
CUMMINS, Volvo PENTA, DOOSAN, DEUTZ, LOVOL, WUXI POWER, GOOGOL, CSR.
World famous brand AC alternator: Stamford, Marathon, Leroy Somer, MVC.
Advanced and reliable controller: Key start, Auto start, AMF & Remote control by PC with RS232 / 485.
Full range protect function and alarm shutdown feature.
Comply with GB/T2820-97, ISO8528 national standard and ISO9001 quality standard.

Alternator Feature
Brushless, 4 poles, rotation magnet.
IP21-23 enclosure is standard for all industrial alternators.
The insulation system is Class H.
Simple installation and maintenance, with easy access to terminals, rotating diodes and coupling bolts.
Wide range of flange adaptors and single bearing disc coupling.
Standard 2/3 pitch windings avoid excessive neutral currents.
Optional accessories available for easy paralleling with mains or other generators.
Optional permanent magnet generator ( PMG ) system provide constant excitation under all condition.
AVR auto voltage regulator, auto exciter, auto adjustment.
Standard: BS5000, VDE0530, NEMA MG1-32, IEC34, IEC60034, AS1359.

Control System
GCS6410 is an Automatic Mains Failure module which is designed to monitor the mains utility and on failure automatically starts the generator and transfers the load. On return of the mains utility the controller automatically returns the load to the mains and stops the generator after a cool down period.
The module also monitors and protects the engine, indicating operational status, fault conditions and metering on the front panel LCD or LED's.
Ture RMS measuring
Configuration of parameters by front panel push buttons or communication software
RS485, RS232, or USB port for remote communication.
Configurable fuel output energise to stop or energise to run.
6 configurable inputs.
3 configurable outputs.
2 analogue inputs configurable for different senders for oil pressure and engine temperature.
With ATS control.

Standard Accessory
Common steel base frame, Damper, Exhaust silencer, Flexible pipe, Battery connecting wires, Operation manual and document.
Optional Accessory
Circuit breaker, Starting battery, Engine coolant and oil heater, Alternator space heater, Cooling for heat exchanger, Control system with RS232/485 communication interface, Battery charger by main supply. Fuel-water separator, Daily fuel tank, ATS & parallelin system, Soundproof canopy and Moving trailer.

Quality Warranty Period
All equipment is guaranteed for a period of 1000 hours running or 12 months from the date when the generator set has been delivered from the factory.
Integrated Power Solutions
Emergency rescue system solutions for mobile power.
Uninterrupted backup power system solutions for villa.
Complex commercial real estate solutions for backup power systems.
Power and pneumatic Integration solutions for mining.
Precision manufacturing and industrial enterprise backup power systems solutions.
Pulp and paper plant backup power systems solutions.
Star hotel and high-level office backup power solutions.
Large data memory center and high-speed generator sets power systems solutions.
Automatic high-speed Integration parallel and the power grid system solutions.
Genset Main Technical Data:                                              
Genset Model GDC400
Prime Power(50HZ) 320kW /400kVA
Standby Power(50HZ) 352kW/440kVA
Frequency/Speed 60Hz/1800rpm
Standard Voltage 220/127V
Phases Three phases, four wires
 reaction for frequency and voltage @ 50% load  in 0.2 S
Regulation accuracy adjustable,normally 1%
(1) PRP: Prime Power is available for an unlimited number of annual operating hours in variable load applications, in
     accordance with ISO8528-1. A 10% overload capability is available for a period of 1 hour within 12-hour period of
     operation. In accordance with ISO 3046-1.
(2) ESP: The Standby Power Rating is applicable for supplying emergency power in variable load applications for
     up to 200 hours per year in accordance with ISO8528-1. Overload is not allowed. 
Generator Engine Performance Data - Cummins
Manufacturer   CHONGQING CUMMINS ENGINE COMPANY LTD.
Model KTA19-G2
Engine speed 1800rpm
Engine power  
--------------------Prime power 392 kW(525 BHP)
--------------------Standby power 448 kW(600 BHP)
Aspiration Turbocharged and Aftercooled
Number of cylinders 6
Type 4 cycle, in-line
Bore * Stroke 159 × 159mm
Displacement 19 L
Compression ratio 14.5:1
Fuel Consumption at full load 184 Lb/h (83Kg/h)
Exhaust system
Maximum Allowable Back Pressure -in.Hg(kPa) 3 (10)
Exhaust Pipe Size Normally Acceptable -in(mm) 5 (127)
Intake Air Alarm Temperature (1500/1800 rpm)-ºC(°F) 82 (180)
Cooling system
After-cooler Only -U.S.Gal(L) 6 (23)
With heat exchanger HX 6076 53
With explantion tank & LTA-U.S.Gal(L) 30 (112)
Fuel system Cummins PT
Emissions control device Turbo, Aftercooling
Exhaust Emissions Data (All values are grams/hp-hour)  
Component  
PM (Particulate Matter) Stanby 0.5, Prime 0.5
SO(Sulfur Dioxide) Stanby 0.61, Prime 0.61
CO(Carbon Dioxide) Stanby 500, Prime 500
N2 (Nitrogen) Stanby 2900, Prime 3100
O2 (Oxygen) Stanby 370, Prime 430
H20 (Water Vapor) Stanby 180, Prime 180
ALTERNATOR Specifications 
Manufacturer   Cummins Generator Technologies
Model HCI444ES
Country of Origin Jiangsu,China
Continuous kVA 500
Continuous kW 400
AVR model AS440
Number of phase 3
Power factor (Cos Phi) 0.8
Altitude ≤ 1000 m
Overspeed 2250Rev/Min
Number of Pole  4
Insulation class  H
Voltage regulation ±0.5%
Protection IP 23
Total harmonics (TGH/THC) < 4 %
Wave form : NEMA = TIF < 50
Wave form :  I.E.C. = THF < 2%
Bearing single
Coupling Direct
Efficiency 93.70%
Generator photos:
400kVA Cummins Silent Diesel Generator for Sale (NTAA85-G7A) (GDC400*S)
400kVA Cummins Silent Diesel Generator for Sale (NTAA85-G7A) (GDC400*S)400kVA Cummins Silent Diesel Generator for Sale (NTAA85-G7A) (GDC400*S)

Contact: Ms Vicki Yuan
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2011

Suppliers with verified business licenses

Rating: 4.0/5
Manufacturer/Factory & Trading Company
Management System Certification
ISO9001:2015
OEM/ODM Availability
Yes