Generator main techinical data
Model | Unit | GDC30*S |
Generator | ||
Frequency | Hz | 50 |
Prime power | kVA (kW) | 30/24 |
Standby power | kVA(kW) | 33/26.4 |
Phase & wires | 1*3 | |
Power factor | 0.8 | |
No. of poles | 4 | |
Insulation | H | |
Voltage regulation | % | ±0.5 |
Excitation system | Brushless | |
Alternator model | PI144G | |
Engine | ||
Brand | Cummins | |
Model | 4BT3.9-G2 | |
No. of cylinders | 3 | |
Bore x stroke | mm | 105*127 |
Displacement | L | 3.3 |
Engine speed | rpm | 1500 |
Rated power | kW/BHP | 28/37 |
Lubrication oil | CH4/15W-40 | |
Oil capacity | L | 7.9 |
Coolant capacity | L | 10.2 |
Governer method | Electric | |
Soundproof Sets | ||
Fuel | Diesel | |
Fuel consumption L/h | at 100% load | 6.7 |
at 75% load | 5.1 | |
Fuel tank capacity | L | 180 |
Continuous runing hours (at 75% load) | 35 | |
Starting system | Electric | |
Length | mm | 2250 |
Width | mm | 1050 |
Height | mm | 1250 |
Approx net weight | kg | 1280 |
Noise level | dBA@7m | 69 |
Open sets | ||
Model | PP30 | |
Length | mm | 1895 |
Width | mm | 700 |
Height | mm | 1400 |
Approx net weight | kg | 730 |
Fuel tank capacity | L | 120 |
Safety
Design, production and testing of the generator sets comply with EU CE safety standard;
Equipped with circuit breaker to avoid possible electric risk at re-startup when engine stops in emergency.
The controller has a historical operation recording function for troubleshooting and inspection.
Powerful Engines
Adopts world-famous engines,with low noise and low emission.
Rugged structure ensures lowest vibration.
Common rail system: (for some models) significantly lowers the combustion temperature, and also leads to cleaner exhaust.
For the turbocharged machines, the carbon dioxide (CO2) emission is reduced.
Control System
Micro-processor cored digital system.
Multiple languages, automatic control.
Connected with the mains through ATS, which can help realize automatic transfer between the mains and the generators. Also, multiple generators can be paralleled for bigger power needs.