• 3 Phase 125kVA 100kw Deutz Engine Silent Diesel Generator (GDD125*S)
  • 3 Phase 125kVA 100kw Deutz Engine Silent Diesel Generator (GDD125*S)
  • 3 Phase 125kVA 100kw Deutz Engine Silent Diesel Generator (GDD125*S)
  • 3 Phase 125kVA 100kw Deutz Engine Silent Diesel Generator (GDD125*S)
  • 3 Phase 125kVA 100kw Deutz Engine Silent Diesel Generator (GDD125*S)
  • 3 Phase 125kVA 100kw Deutz Engine Silent Diesel Generator (GDD125*S)

3 Phase 125kVA 100kw Deutz Engine Silent Diesel Generator (GDD125*S)

After-sales Service: 24 Hours Online
Warranty: One Year or 1000 Working Hours From The Shipment D
Type: Basic Diesel Generator
Installation Method: Fixed
Stroke: Four Stroke
Cooling Method: Water Cooling
Customization:
Diamond Member Since 2011

Suppliers with verified business licenses

Rating: 4.0/5
Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
GDD125*S
Output Type
AC Three Phase
Speed
Speed
Conditions of Use
Land Use
Usage
Common Units
Landuse Type of Unit
Ordinary
Excitation Mode
AC Rotating Exciter
Engine
Deutz Brand, Cummins, Doosan Is Optiona;
Alternator
Stamford, Marathon, Engaa, Leroy Somer
Controller
Dse, Smartgen Is Optional
Test Load
25%, 50%, 75%, 100%, 110%
Voltage Range
110V-690V
Transport Package
in Strong Plywood
Specification
IECBS 5000, IEC 34, CCC, CE, ISO9001, SGS
Trademark
GODLIKE (OEM supported)
Origin
Yangzhou, Jiangsu, China
HS Code
8502120000
Production Capacity
8000sets/Year

Product Description

3 Phase 125kVA 100kW Deutz Engine Silent Diesel Generator (GDD125*S)

Specifications
1) Power range: 125kVA /100kw
2) Brushless Synchronous A. C. Alternator,
3) Stamford& Leroy somer Type of Electric Generator,
4) Three Phase optional, IP23, Class H,
5) Rated voltage 400V, 110-690V option

Scope of Supply:
1-Brand new engine and brushless AVR controlled alternator
2-Set mounted Smartgen Auto Controller
3-MCCB(Circuit Breaker), Emergency stop button, low oil pressure shutdown, high engine temperature shutdown.
4-Rubber Anti Vibration Mounts and skid basefram with 6-8hours integral fuel tank.
5-Genset equipped with battery charger and 24V high performance lead acid starting batteires and connecting with cables.
6-Genset equipped with industrial silencer and flexible exhaust hose.
7-Genset equipped with fan and closed circuit cooled radiator(40degree centigrade).
8-Genset with filtering systems including air filter, fuel filter & lub-oil filter.
9-Supply relative documents(testing report, diagram, operation/maintenance manual/spare parts manuals)for engine and alternator

Engine specification
1.8kw-1000kw Diesel engine
2. Multi-cylinder in-line or veer engine, 4-stroke, direct injection
3. Naturally aspirated, turbocharged, water cooled or turbocharged with air intercooler
4. Machinery or electronic governing
5. Fuel injection pump
6. Electric motor starting system
7. Forged steel crankshaft, cast iron cylinder and replaceable wet type cylinder liner
8. Low discharge, and low fuel consumption

Alternator: Stamford
Option with: Marathon, Leroy somer,
A) three phase brushless generator, self-excited, 4-pole, single bearing
B) AVR self-regulated, voltage regulation rate ≤ ± 1%
C) IP23 protection grade
D) Class H insulation
E) Radio interference restraining accords with stipulation of VDE0875-N and ISO8528
F) Moistureproof, sand-proof, dustproof, salt-proof and vibration-proof

Control system:
1. Automatic cutter which is suitable for the generator power
2. Turn on key
3. A device to measure the generators speed
4. Counter for measuring the Operating hours
5. Device to measure the current overload with a switched current
6. A device to measure the battery voltage
7. Voltmeter with a voltage exchanger
8. A device to measure the frequency
9. Thermostat to regulate the voltage
10. A device to measure the oil pressure
11. Alerting lamps indicating low and high temperature
12. Controller of the current increase and short circuit
13. Emergency stop button

Warranty:
12 months or 1000 running hours from shipment date. If the quality problem arise during the warranty period, and verified the problem is caused by our genset-body instead of external or natural reasons. (Refer to all kinds of natural disaster, shipping, loading, unloading, wrong-operation, etc), we will supply the relevant spare parts free of charge for maintenance; After the warranty period, we can supply the required spare parts for you under cost prices
Our service quality assurance:
1)Before-sale Service: We provide detailed product technical parameters for equipment choosing and system designing
2)Service quality assurance: Our sale staffs are all experience and professional, who can provide the most proper system design and optimized equipment for the customers.
3)After sale maintenance service: We create files for end user and provide them follow-up service, regular return visit and permanent maintenance.
genset Model  GDD125*S
SET Genset model GDD125*S
Output power 100kW
Power factor 0.8(lagging)
Output voltage 400V/230V
Output current 180A
Rrted Freguency 50hz
Rated Rotating speed 1500rpm
The grade of fuel (standard)0#light diesel (normal)  
Dimension 2490*720*1500(L*W*H mm)
Genset weight 1150kg
Voltage Regulation steady state(%) ≤±1 
Voltage fluctuation rate(%) ≤±0.5
Voltage regulation transient state(%)   +20~-15
Voltage stability time(s) ≤1
Reguency regulation steady state(%) ≤±1
Requency fluctuation rate(%) ≤±0.5
Requency regulation transient state (%) +10~-7
Reguency stability time(s) ≤3
Fuel consumption at 100% load  ≤209g/kw*h
Nose(LP7m) 95dB(A)
ENGINE Place of origin/brand DEUTZ
Diesel engine model TBD226B-6D
Number of cylinders 6/L model
Bore*stroke 105×120 mm
Compression ratio  15.5:1
Starting method DC24V Electrical starting
Cooling system  Closed water circulation cooling
Oil way  Direct injection
Intake way  Turbocharge
Overload capacity 110%
Rotating speed 1500rpm
ALTERNATOR Place of origin/brand GODLIKE
Alternator model JDG274D
Rated power  100Kw
Rated voltage 400V/230V
Insulation class H class
Protection class IP22
Connecting type 3phase4wires Y type
Accommodation type AVR 
Output frequency 50hz
Output factor 0.8(lagging)
Germany Deutz Air-cooled generator configuration and technical data

50HZ, 3 Phases, 400V
No. GENSET
Model
OUTPUT POWER 
1500RPM 50HZ
Engine Model Alternator Model Bore*Stroke Cyl. Disp. Fuel Cons.
Prime
KVA
Prime
KW
Standby
KVA
standby
KW
Deutz GODLIKE Stamford (mm) Nos (L) g/kw.h
1 GDD15*S 15 12 17 13 F2L912 JDG164D BCI164D 100*120 2 1.9 ≤249
2 GDD20*S 20 16 22 18 F3L912 JDG184E BCI164E 100*120 3 2.8 ≤249
3 GDD25*S 25 20 28 22 F3L912 JDG184F BCI184F 100*120 3 2.8 ≤249
4 GDD30*S 30 24 33 26 F4L912 JDG184G BCI184G 100*120 4 3.8 ≤249
5 GDD33*S 33 26 36 29 F4L913 JDG184H BCI184H 100*120 4 3.8 ≤249
6 GDD38*S 38 30 41 33 F4L912T JDG184H BCI184H 102*125 4 3.8 ≤249
7 GDD43*S 43 34 47 37 F4L912T JDG184J BCI184J 102*125 4 3.8 ≤249
8 GDD50*S 50 40 55 44 F6L912 JDG224D UCI224D 100*120 6 5.7 ≤251
9 GDD53*S 53 42 58 46 BF6L913 JDG224ES UCI224E 102*125 6 6.1 ≤251
10 GDD60*S 60 48 66 53 F6L912T JDG224E  UCI224E 102*125 6 5.7 ≤251
11 GDD69*S 69 55 76 61 BF6L913 JDF224F UCI224F 102*125 6 6.1 ≤251
12 GDD94*S 94 75 103 83 BF6L913C JDG224H UCI274C 102*125 6 6.1 ≤251
13 GDD113*S 113 90 124 99 F8L413F JDG274DS UCI274D 125*130 8 12.8 ≤206
14 GDD150*S 150 120 165 132 BF8L513 JDG274E UCI274F 125*130 8 12.8 ≤206
15 GDD188*S 188 150 206 165 BF8L513C JDG274G UCI274H 125*130 8 12.8 ≤206
60HZ, 3 Phases, 220V
No. GENSET
Model
OUTPUT POWER 
1800RPM 60HZ
Engine Model Alternator Model Bore*Stroke Cyl. Disp. Fuel Cons.
Prime
KVA
Prime
KW
Standby
KVA
standby
KW
Deutz GODLIKE Stamford (mm) Nos (L) g/kw.h
1 GDD16X*S 16 13 18 14 F2L912 JDG164C BCI164D 100*120 2 1.9 ≤249
2 GDD29X*S 29 23 32 25 F3L912 JDG184E BCI184E 100*120 3 2.8 ≤249
3 GDD34X*S 34 27 37 30 F3L913 JDG184F BCI184F 102*125 3 2.8 ≤249
4 GDD38X*S 38 30 41 33 F4L912 JDG184G BCI184F 100*120 4 3.8 ≤249
5 GDD43X*S 43 34 47 37 F4L913 JDG184H BCI184G 102*125 4 3.8 ≤249
6 GDD61X*S 61 49 67 54 F6L912 JDG224D BCI184J 100*120 6 5.7 ≤249
7 GDD73X*S 73 58 80 64 F6L913 JDG224E   UCI224D 102*125 6 6.1 ≤251
8 GDD80X*S 80 64 88 70 F6L912T JDG224E   UCI224D 100*125 6 6.1 ≤251
9 GDD88X*S 88 70 96 77 BF6L913 JDG224F UCI224G 102*125 6 6.1 ≤251
10 GDD119X*S 119 95 131 105 F6L913C JDG274C UCI224G 102*125 6 6.1 ≤251
Generator photos:
3 Phase 125kVA 100kw Deutz Engine Silent Diesel Generator (GDD125*S)3 Phase 125kVA 100kw Deutz Engine Silent Diesel Generator (GDD125*S)3 Phase 125kVA 100kw Deutz Engine Silent Diesel Generator (GDD125*S)
Contact: Ms Vicki Yuan
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2011

Suppliers with verified business licenses

Rating: 4.0/5
Manufacturer/Factory & Trading Company
Management System Certification
ISO9001:2015
OEM/ODM Availability
Yes